IP65 Tempered Glass Sterile Luminaires

Product Information

Body 0,50 mm thick metal frame with electrostatic powder coating
Glass Tempered clear glass
Reflector 0,40 mm thick “anodized aluminium reflector” maintaining its optical properties, non-yellowing and nondiscolouring throughout lifetime of the luminaire
Technical Information
Code NoPower (W)Luminous Flux (lm)Dimensions ((mm) a b c)Weight (kg)Volume (m3)BasePcs/PackCurrentLamp TypePower FactorRal CodeBalast TypeSize Of The Hole (mm)
5014 51622x182x1300595x295x10021.70.0652G1340.18TL-D>0.959016Electronic575x275
5014 51324x184x1300595x595x10026.40.978G1330.34TL-D>0.959016Electronic575x575
5014 51722x362x32501195x295x10026.40.128G1330.305TL-D>0.959016Electronic1175x275
5055 04622x242x1750595x295x10021.70.0652G540.23TL5>0.959016Electronic575x275
5055 04724x244x1750595x595x10026.40.978G530.43TL5>0.959016Electronic575x575
5055 04422x282x25801195x295x10026.40.128G540,18TL5>0.959016Electronic1175x275
Product Features

Mechanical Specifications

  • 0,50 mm thick metal frame with electrostatic powder coating.
  • Stainless steel latches positioned to prevent falling of the framework.
  • Ceiling tile compatible model including 4 extra brackets for drywall ceiling installations

Electrical Specifications

  • A2 class, low-loss electronic ballast with over 50.000-hours lifetime.
  • Long lamp lifetime due to hot ignition property of the ballast enabling minimum 50.000 switching cycles.
  • Efficient power factor correction immune to fluctuations in grid voltage and providing constant light output.
  • “Halogen-free” internal wiring.
  • Non-flammable connector terminal suitable for 2,5mm² crosssectioned cable installation.

Optical Specifications

  • 0,40 mm thick “anodized aluminium reflector” maintaining its optical properties
  • non-yellowing and nondiscolouring throughout lifetime of the luminaire.
  • Anti-glare, highly reflective lamellae.
  • Transparent tempered glass high transmission diffuser providing IK08 conditions and resistant to high temperatures and impacts.

Options

  • DALI and corridor function applications.
  • B2 Class Electromagnetic ballast application.
  • Emergency lighting unit application up to 3 hours.
  • Different number of lamellae and matt reflector applications.
  • Metal suspended ceiling application
Photometric Data
Usage Areas
  • HOSPITALS
  • OPERATION ROOMS
  • INDUSTRIAL KITCHENS
  • LABORATORIES

Product Standarts

  • Derece işareti
  • IP 65
  • Işık hüzmesi
  • EN 60598-2-2